Ultimate Load: 15,625 pounds (69,500 N)
Max Rated Release Load: 12,500 pounds (55,600 N)
**Source Shock: <500 g’s @ 12,500 lb. preload
Actuation Circuit: 4 Amps @ 6 VDC per circuit
Actuation Time: 25 milliseconds maximum
Qual Temperature Range: -60°C to +105°C
Weight: 1.8 pounds (816 g) maximum
* All values are based on Qualification Test results. These values do not necessarily
represent limits of the device.
** Level of Source Shock depends on length of release rod. Data shown is for
rod 6”(150mm) long or less.