Ultimate Load: 6,500 pounds (29,000 N)
Rated Release Load: 5,700 pounds ( 26,000 N)
Source Shock: <100 g’s
Actuation Circuit: 4 Amps @ 4 VDC per circuit
Actuation Time: 25 milliseconds maximum
Temperature Range: -80°C to +150°C
Weight: 160 grams (including 12”(300mm) cable)
* All values are based on Qualification Test results. These values do not
necessarily represent limits of the device.