Ultimate Load: 6,200 pounds (28,000 N)
Rated Release Load: 4,500 pounds (20,300 N)
Source Shock: <50 g’s @ 2500 # preload
Actuation Circuit: 4 Amps @ 4 VDC
Actuation Time: 25 milliseconds maximum
Temperature Range: -80°C to 150°C
Weight: 80 grams
* All values are based on Test results. These values do not necessarily represent
limits of the device.